<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>PV questions &#8211; Imeon Energy</title>
	<atom:link href="https://imeon-energy.co.za/cat/faq-za/pv-questions-en-za/feed/" rel="self" type="application/rss+xml" />
	<link>https://imeon-energy.co.za</link>
	<description>Your Power, Your Rules</description>
	<lastBuildDate>Tue, 25 Feb 2020 14:17:06 +0000</lastBuildDate>
	<language>en-ZA</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://imeon-energy.co.za/wp-content/uploads/cropped-imeon-icon-logo-favicon-2-32x32.png</url>
	<title>PV questions &#8211; Imeon Energy</title>
	<link>https://imeon-energy.co.za</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Which solar panels can be used with Imeon?</title>
		<link>https://imeon-energy.co.za/faq-za/pv-questions-en-za/which-solar-panels-can-be-used-with-imeon/</link>
		
		<dc:creator><![CDATA[IMEON ENERGY]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 15:51:52 +0000</pubDate>
				<category><![CDATA[FAQ]]></category>
		<category><![CDATA[PV questions]]></category>
		<guid isPermaLink="false">https://imeon-energy.com/non-classifiee/which-solar-panels-can-be-used-with-imeon/</guid>

					<description><![CDATA[Because Imeon inverter is compatible with mono and poly crystalline solar panels. Do not connect any solar panels that may introduce leakage current to the inverter (such as non-grounded PV modules). NOTE : The PV DC voltage and current must be within the range of the MPPT Input specified in the datasheets and technical documentation [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Because Imeon inverter is compatible with mono and poly crystalline solar panels. Do not connect any solar panels that may introduce leakage current to the inverter (such as non-grounded PV modules).</p>
<p>NOTE : The PV DC voltage and current must be within the range of the MPPT Input specified in the datasheets and technical documentation of IMEON products.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Detection of photovoltaic panels</title>
		<link>https://imeon-energy.co.za/faq-za/pv-questions-en-za/the-inverter-does-not-detect-the-pv-2/</link>
		
		<dc:creator><![CDATA[IMEON ENERGY]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 14:01:52 +0000</pubDate>
				<category><![CDATA[PV questions]]></category>
		<guid isPermaLink="false">https://imeon-energy.com/non-classifiee/the-inverter-does-not-detect-the-pv-2/</guid>

					<description><![CDATA[For the detection of photovoltaic panels Open the circuit breaker between the PV and the inverter and measure the DC voltage between (+) and (-) terminals of the PV string. NOTE: The PV DC voltage and current must be within the range of the MPPT Input. Refer to product documentation. NOTE: Keep in mind to [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>For the detection of photovoltaic panels</p>
<p>Open the circuit breaker between the PV and the inverter and measure the DC voltage between (+) and (-) terminals of the PV string.<br />
NOTE: The PV DC voltage and current must be within the range of the MPPT Input. Refer to product documentation.<br />
NOTE: Keep in mind to take into account the difference between the open circuit voltage and nominal voltage of your PV array. If you’re measuring Voc that is slightly above the inverter’s minimum MPPT input voltage, it’s very likely that the Vmp voltage will be below minimum MPPT input voltage.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to find out the maximum PV generated power:</title>
		<link>https://imeon-energy.co.za/faq-za/pv-questions-en-za/how-to-find-out-the-maximum-pv-generated-power/</link>
		
		<dc:creator><![CDATA[IMEON ENERGY]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 10:28:22 +0000</pubDate>
				<category><![CDATA[PV questions]]></category>
		<guid isPermaLink="false">https://imeon-energy.com/non-classifiee/how-to-find-out-the-maximum-pv-generated-power/</guid>

					<description><![CDATA[PV modules are subject to standard test conditions that are defined with particularly strict certifications (IEC, ISO). From idealistic radiance test conditions (1000W/m² at 25°C) result the provided voltages, currents and temperature factors that you can read from your PV modules specifications. Note that temperature plays an important role: an increase in temperature can result [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>PV modules are subject to standard test conditions that are defined with particularly strict certifications (IEC, ISO).  From idealistic radiance test conditions (1000W/m² at 25°C) result the provided voltages, currents and temperature factors that you can read from your PV modules specifications. Note that temperature plays an important role: an increase in temperature can result in modules generating less power. You must also consider all possible cable losses (PV installation) that can count for 3% and a 1% maximum in the mppt yield.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>What are the priorities of IMEON solar production management?</title>
		<link>https://imeon-energy.co.za/faq-za/pv-questions-en-za/how-production-is-managed-by-imeon/</link>
		
		<dc:creator><![CDATA[IMEON ENERGY]]></dc:creator>
		<pubDate>Mon, 26 Feb 2018 10:08:49 +0000</pubDate>
				<category><![CDATA[FAQ]]></category>
		<category><![CDATA[PV questions]]></category>
		<guid isPermaLink="false">https://imeon-energy.com/non-classifiee/how-production-is-managed-by-imeon/</guid>

					<description><![CDATA[Depending on the mode in which the IMEON hybrid inverter is programmed, the priorities for using the electricity generated by the solar installation will be as follows: With the hybrid IMEON inverter programmed in smart-grid mode: direct consumption of the solar production then charge of the batteries then injection to the grid. With the hybrid [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><span id="result_box" class="" lang="en" tabindex="-1"><span title="En fonction du mode dans lequel est programmé l' onduleur hybride IMEON, les priorités d'utilisation de l'électricité générée par l'installation solaire seront les suivantes:

    ">Depending on the mode in which the IMEON hybrid inverter is programmed, the priorities for using the electricity generated by the solar installation will be as follows:</span></span></p>
<p><span id="result_box" class="" lang="en" tabindex="-1"><span title="avec l' onduleur hybride IMEON programmé en mode smart-grid:

">With the hybrid IMEON inverter programmed in smart-grid mode:</span></span></p>
<ul>
<li><span id="result_box" class="" lang="en" tabindex="-1"><span title="consommation directe de la production solaire puis charge des batteries puis injection sur le réseau public de distribution d'électricité

    ">direct consumption of the solar production then charge of the batteries then injection to the grid.<br />
</span></span></li>
</ul>
<p><span id="result_box" class="" lang="en" tabindex="-1"><span title="consommation directe de la production solaire puis charge des batteries puis injection sur le réseau public de distribution d'électricité

    ">W</span><span title="avec l' onduleur hybride IMEON programmé en mode off-grid:

">ith the hybrid inverter IMEON programmed in off-grid mode:</span></span></p>
<ul>
<li><span id="result_box" class="" lang="en" tabindex="-1"><span title="charge du parc de batteries puis alimentation des consommateurs.">charge of the battery bank then supply of the loads. </span><span title="Dans ce mode, dédié à l'électrification de sites isolé, il n'est pas possible d'injecter d'énergie en direction du réseau public de distribution d'électricité.

    ">In this mode, dedicated to the electrification of isolated sites, it is not possible to inject energy to grid.</span></span></li>
</ul>
<p><span id="result_box" class="" lang="en" tabindex="-1"><span title="avec l' onduleur hybride IMEON programmé en mode back-up:

">With the hybrid IMEON UPS programmed in back-up mode:</span></span></p>
<ul>
<li><span id="result_box" class="" lang="en" tabindex="-1"><span title="charge du parc de batteries puis alimentation des consommateurs puis injection sur le réseau public de distribution d'électricité.

    ">charge of the battery bank then supply of the loads then injectionto grid. </span></span></li>
</ul>
<p><span id="result_box" class="" lang="en" tabindex="-1"><span title="charge du parc de batteries puis alimentation des consommateurs puis injection sur le réseau public de distribution d'électricité.

    ">W</span><span title="avec l' onduleur hybride IMEON programmé en mode on-grid:

">ith the IMEON hybrid inverter programmed in on-grid mode:</span></span></p>
<ul>
<li><span id="result_box" class="" lang="en" tabindex="-1"><span title="la totalité de la production est injectée sur le réseau public de distribution d'électricité.

">all production is injected into grid.</span></span></li>
</ul>
<p><span id="result_box" class="" lang="en" tabindex="-1"><span title="Il est possible, dans les modes back-up et smart-grid d'interdire l'injection d'électricité sur le réseau public de distribution d'électricité.">It is possible, in the back-up and smart-grid modes, to disable the injection of electricity into the grid.</span></span></p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/?utm_source=w3tc&utm_medium=footer_comment&utm_campaign=free_plugin

Page Caching using Disk: Enhanced 
Database Caching 5/150 queries in 0.749 seconds using Disk (Request-wide modification query)

Served from: imeon-energy.co.za @ 2026-05-08 12:26:38 by W3 Total Cache
-->